CBNNC - TEMPO INTERIOR VINYL ACRYLIC CEILING WHITE,01040/1-40

  • MSDS: CBNNC
  • Manufacturer: MCCORMICK PAINTS
  • Product Name: TEMPO INTERIOR VINYL ACRYLIC CEILING WHITE,01040/1-40
  • National Stock Number: 8010-00N071293
Product Identification

Product ID:TEMPO INTERIOR VINYL ACRYLIC CEILING WHITE,01040/1-40
MSDS Date:12/15/1993
FSC:8010
NIIN:00N071293
MSDS Number: CBNNC

Responsible Party
MCCORMICK PAINTS
2355 LEWIS AVE
ROCKVILLE, MD 20851
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 301-770-3235

Cage: 0EKH6

Contractor
MCCORMICK PAINTS
ROCKVILLE, MD 20851 US

Telephone: 301-770-3235

Cage: 0EKH6

Ingredients

DIATOMACEOUS EARTH (CONTAINING INGREDIENT 2)

Fraction By Weight: 8%

OSHA PEL N/K

ACGIH TLV: N/K


SILICA, CRYSTALLINE - CRISTOBALITE

CAS: 14464-46-1

RTECS: VV7325000

Fraction By Weight: 35%

OSHA PEL SEE TABLE Z-3

ACGIH TLV: 0.05 MG/M3 RDUST

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION: VAPORS OR SPRAY
MISTS MAY BE IRRITATING TO EYES, NOSE, THROAT AND MUCOUS MEMBRANES
OF THE RESPIRATORY TRACT PRODUCING SYMPTOMS OF HEADACHE AND/OR
NAUSEA IN POORLY VENTILATED AREAS.
Explanation of Carcinogenicity:SILICA, CRYSTALLINE-CRISTOBALITE: IARC
MONOGRAPHS, SUPPLEMENT, VOLUME 7, PAGE 341, 1987: GROUP 2A. (SUP
DAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:SKIN CONTACT: PROLONGED OR REPEATED
CONTACT WITH COATING MAY CAUSE SKIN IRRITATION. EYE CONTACT: DIRECT
EYE CONTACT WILL CAUSE IRRITATION.

First Aid

First Aid:SKIN: WASH THOROUGHLY WITH SOAP AND WATER. EYES: IMMEDIATELY
FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. CONSULT MD.
INGESTION: IF VICTIM IS CONSCIOUS, GIVE 2 GLASSES OF WATER AND CALL
MD. INH ALATION: REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE
OXYGEN OR ARTIFICIAL RESPIRATION) .

Fire Fighting

Extinguishing Media:USE WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:CONTAIN SPILL AND REMOVE WITH INERT MATERIAL
(SAND, EARTH, ABSORBENT). KEEP SPILL OUT OF SEWERS AND OPEN BODIES
OF WATER. KEEP UNNECESSARY PEOPLE AWAY, AS FLOOR MAY BE SLIPPERY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE ABOVE 34F AND BELOW 140F. DO NOT
TAKE INTERNALLY.
Other Precautions:THIS COATING CONTAINS MATLS CLASSIFIED AS NUISANCE
PARTICULATES, FOR EXAMPLE TITANIUM DIOXIDE, CALCIUM CARBONATE, ETC,
WHICH MAY BE PRESENT AT HAZARDOUS LEVELS ONLY DURING SPRAYING THIS
COATING OR SAN DING OR ABRADING OF THE DRIED FILM.

Exposure Controls

Respiratory Protection:NONE REQUIRED IF GOOD VENTILATION IS MAINTAINED
EXCEPT IF PRODUCT IS SPRAYED, THEN USE MASK (NIOSH/MSHA APPROVED).
IF TLV IS EXCEEDED THEN USE NIOSH/MSHA APPROVED CANISTER OR AIR
HOSE MASK.
Ventilation:MECHANICAL-LOCAL EXHAUST AT POINT OF CONTAMINANT RELEASE
(VAPOR, MIST OR DUST).
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS BEFORE EATING OR USING BATHROOM.
Supplemental Safety and Health
EXPLAN OF CARCIN: NTP 7TH ANNUAL REPORT ON CARCINOGENS, 1994:
ANTICIPATED TO BE CARCINOGEN.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Density:LTR/AIR
Spec Gravity:1.51
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:60

Stability

Stability Indicator/Materials to Avoid:YES
ANY MATERIAL THAT REACTS VIOLENTLY WITH WATER.
Stability Condition to Avoid:FREEZING OR TEMPERATURES OVER 140F.
Hazardous Decomposition Products:ACETIC ACID, CARBON MONOXIDE AND
CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.